Digital high speed pyrometer for laser, industry and R&D with Ethernet connection and display

Properties:

  • For extremely fast temperature measurements (10 µs) for lasers, industry, research and development
  • Measuring fields from 0.3 mm
  • Very high accuracy
  • LED pilot light
  • Large continuous measuring ranges from 160 ... 3.500 °CC
  • Customer-specific adaptation to an application
  • Configurable linear current output 0 (4) ... 20 mA
  • Large configurable display
  • Configurable switching mark with state indicator in the display
  • Ethernet and RS 485 communication interface
  • Parameterization on the PC with the help of the software Pyroskop Control
  • Real-time recording and display of measurement curves on the PC
  • Direct optics (vario and macro optics) as well as fiber optics available

Applications:

  • Welding, hardening, soldering (also for laser applications)
  • Turbine buckets
  • Combustions engines
  • Material testing and -development
  • Airbag testing
  • Explosion events
  • Monitoring of temperatures
  • Recording temperatures
  • Analysis of temperature recordings

Materials:

  • Metals
  • Synthetic materials
  • Ceramics

Measurement ranges:

  • 600 ... 1,600 °C (0.85 ... 1.05 µm)
  • 800 ... 2,300 °C (0.85 ... 1.05 µm)
  • 300 ... 1,400 °C (1.58 ... 1.80 µm)
  • 500 ... 2,500 °C (1.58 ... 1.80 µm)
  • 160 ... 1,000 °C (1.58 ... 2.20 µm) (Only for pyrometers with direct optics)
  • 200 ... 1,000 °C (1.58 ... 2.20 µm)
  • 400 ... 1,300 °C (1.58 ... 2.20 µm)
  • 300 ... 2,300 °C (2.00 ... 2.20 µm)
  • 400 ... 3,000 °C (2.00 ... 2.20 µm)
  • 350 ... 3,500 °C (2.00 ... 2.20 µm)

Optics:

  • The pyrometers are available with direct-optics (vario and macro optics) as well as with fibre optics
  • The fiber optics are available as vario and fixed optics in different versions. These can be found here.
  • The measuring field diameter of the vario optics can be adjusted from 2.5 mm (measurement distance 450 mm) to 28.0 mm (measurement distance 3000 mm)
  • The measuring field diameter of the macro optics is 0.7 mm (with used spectral ranges of 0.85 ... 1.05 µm and 1.58 ... 1.80 µm) as well as 1.0 mm (with spectral ranges of 1.58 ... 2.20 µm and 2.00 ... 2.20 µm)

Accessories:

  • Suitable accessories can be found here.
Media